Csst shall be listed in accordance with
WebSep 12, 2013 · The bonding jumper shall connect to a metallic pipe or fitting between the point of delivery and the first downstream CSST fitting. The bonding jumper shall be not smaller than 6 AWG copper wire or equivalent. Gas piping systems that contain one or more segments of CSST shall be bonded in accordance with this section. Web(1) Other than Corrugated Stainless Steel Tubing (CSST). The bonding jumper(s) shall be sized in accordance with Table E3908.12, using the rating of the circuit capable of energizing the piping. The equipment grounding conductor for the circuit that is capable of energizing the piping shall be permitted to serve as the bonding means. (2) CSST.
Csst shall be listed in accordance with
Did you know?
WebCSST gas piping systems shall be bonded to the electrical-service grounding electrode system. The bonding jumper shall connect to metal pipe or fitting between the point of delivery and the first downstream CSST fitting. ... Pipe sizing tables or sizing equations in accordance with Equations 24-3 or 24-4. The sizing table included in a listed ... WebApr 19, 2015 · The bonding conductor shall beinstalled and protected in accordance with the National Electrical Code, NFPA 70, (NEC) and Canadian Electrical Code …
WebThe Construction Site Safety Technician (CSST) course is designed for industry safety professionals, company safety officers, current site safety coordinators or foremen … WebCorrugated stainless steel tubing (CSST) is generally recognized as a yellow, flexible gas line installed to gas fireplaces, gas stoves, and gas dryers. CSST has been installed in …
WebSep 20, 2001 · "5.6.3.4.1C orrugated stainless steel tubing (CSST) shall be listed in accordance with ANSI LC 1/CSA 6.26, Fuel Gas Piping Systems Using Corrugated … WebG2411.3 (310.3) Arc-Resistant CSST. This section applies to corrugated stainless steel tubing (CSST) that is listed with an arc-resistant jacket or coating system in accordance with ANSI LC1/CSA 6.26. The CSST shall be electrically continuous and bonded to an effective ground fault current path. Where any CSST component of a piping system does ...
WebMay 7, 2013 · NFPA 54 7.13.2 IFGC 310.1.1 IRC G2511.1.1 CSST gas piping systems shall be bonded to the electrical service grounding electrode system. The bonding jumper shall connect to a metalic pipe or fitting BETWEEN THE POINT OF DELIVERY AND THE FIRST DOWNSTREAM CSST FITTING.
WebCSST shall be considered to be bonded when it is connected to appliances that are connected to the appliance grounding conductor of the circuit supplying that appliance. 7.13.2 CSST. CSST gas piping systems shall be bonded to the electrical service grounding electrode system at the point where the gas service enters the building. The portland oregon seafood restaurants bestWebA gas piping system that contains any CSST shall be electrically continuous and shall be directly bonded to the electrical service grounding electrode system. No portion of the gas piping system shall be used as or considered to be a grounding electrode or a grounding electrode conductor. CSST shall be installed and bonded in accordance with Section … portland oregon senior housingWeb• CSST listed in accordance with ANSI LC 1/CSA 6.26, Fuel Gas Piping Systems Using Corrugated Stainless Steel Tubing (CSST). • Installed in accordance with the … optimizing brain healthWebTraductions en contexte de "in accordance with their own specific criteria" en anglais-français avec Reverso Context : The latter make the decision to select or reject the application in accordance with their own specific criteria. Traduction Context Correcteur Synonymes Conjugaison. portland oregon security jobsWebCSST listed with an arc resistant jacket or coating system in accordance with CSA LC 1 shall be electrically continuous and bonded to an effective ground fault current path. Where any CSST component of a piping system does not have an arc-resistant jacket or coating system, the bonding requirements of Section 1211.2 shall apply. Arc-resistant jacketed … portland oregon section 8 applicationWebJul 15, 2024 · Devices used for making the bonding connections shall be listed for the application in accordance with UL 467. 310.3. Arc-resistant CSST. This section applies to corrugated stainless steel tubing (CSST) that is listed with an arc-resistant jacket or coating system in accordance with ANSI LC 1/CSA 6.26. portland oregon schools spring break 2023WebQuality Assurance - TracPipe CounterStrike CSST shall be listed by CSA International to the performance requirements of ANSI LC 1 / CSA 6.26. The conductive jacket shall meet the requirements ... - Flexible gas piping shall be bonded in accordance with the National Electrical Code NFPA 70 Article 250.104 and the National Gas Code NFPA 54, and ... optimizing a laptop for gaming